Offer details
Description
The HP 2810 Switch Series consists of two switches: the 24-port HP 2810-24G Switch with 20 10/100/1000 ports, and the 48-port HP 2810-48G Switch with 44 10/100/1000 ports. Each switch also has four dual-personality ports for RJ-45 10/100/1000 or mini-GBIC fiber Gigabit connectivity. Ideal for high-performance and secure 10/100/1000 connectivity, the 2810 switch series offers access security and advanced prioritization and traffic-monitoring capabilities. The series is cost-effective and easy to use, with a shallow, 1U form factor that provides operational flexibility for use in smaller wiring closets.
Quality of Service (QoS)
• Class of Service (CoS): sets the IEEE 802.1p priority tag based on IP address, IP Type of Service (ToS), Layer 3 protocol, TCP/UDP port number, source port, and DiffServ
Connectivity
• Dual-personality functionality: four 10/100/1000 ports or SFP slots for optional fiber connectivity such as Gigabit-SX, -LX, and -LH, or 100-FX
Resiliency and high availability
• IEEE 802.3ad Link Aggregation Protocol (LACP) and HP port trunking: support up to 24 trunks, each with up to 8 links (ports) per trunk
Manageability
• sFlow (RFC 3176): wire-speed traffic accounting and monitoring
Layer 2 switching
• VLAN support and tagging: supports IEEE 802.1Q (4,094 VLAN IDs) and 256 VLANs simultaneously
Security
• Port security: allows access only to specified MAC addresses, which can be learned or specified by the administrator
Convergence
• IP multicast snooping and data-driven IGMP: automatically prevent flooding of IP multicast traffic
Quality of Service (QoS)
• Class of Service (CoS): sets the IEEE 802.1p priority tag based on IP address, IP Type of Service (ToS), Layer 3 protocol, TCP/UDP port number, source port, and DiffServ
Connectivity
• Dual-personality functionality: four 10/100/1000 ports or SFP slots for optional fiber connectivity such as Gigabit-SX, -LX, and -LH, or 100-FX
Resiliency and high availability
• IEEE 802.3ad Link Aggregation Protocol (LACP) and HP port trunking: support up to 24 trunks, each with up to 8 links (ports) per trunk
Manageability
• sFlow (RFC 3176): wire-speed traffic accounting and monitoring
Layer 2 switching
• VLAN support and tagging: supports IEEE 802.1Q (4,094 VLAN IDs) and 256 VLANs simultaneously
Security
• Port security: allows access only to specified MAC addresses, which can be learned or specified by the administrator
Convergence
• IP multicast snooping and data-driven IGMP: automatically prevent flooding of IP multicast traffic
Specifications
Menedzsment funkciók | |
---|---|
Kapcsoló típusa | Vezérelt |
Csatlakozók és csatlakozási felületek | |
Alapvető kapcsolási RJ-45 Ethernet portok száma | 48 |
Adatátvitel | |
MAC-címtábla | 8000 bejegyzés(ek) |
Áteresztőképesség | up to 71.4 million pps |
Maximális adatátviteli sebesség | 1 Gbit/s |
Biztonság | |
MAC-cím szűrés | Igen |
Protokollok | |
Kapcsolási protokollok | Ethernet |
Támogatott protokollok | Network Management Device Management MIBs General Protocols IEEE 802.1X Port Based Network Access Control; RFC 1492 TACACS+; RFC 2138 RADIUS Authentication; RFC 2866 RADIUS Accounting; Secure Sockets Layer (SSL); SSHv2 Secure Shell IEEE 802.1AB Link Layer Discovery Protocol (LLDP); RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events); RFC 3176 sFlow; SNMPv1/v2c/v3 IEEE 802.1D MAC Bridges; IEEE 802.1p Priority; IEEE 802.1Q VLANs; IEEE 802.1s Multiple Spanning Trees; IEEE 802.1w Rapid Reconfiguration of Spanning Tree; IEEE 802.3ad Link Aggregation Control Protocol (LACP); IEEE 802.3x Flow Control; RFC 768 UDP; RFC 783 TFTP Protocol (revision 2); RFC 792 ICMP; RFC 793 TCP; RFC 826 ARP; RFC 854 TELNET; RFC 951 BOOTP; RFC 1542 BOOTP Extensions; RFC 2030 Simple Network Time Protocol (SNTP) v4 RFC 1213 MIB II; RFC 1493 Bridge MIB; RFC 1573 SNMP MIB II; RFC 2021 RMONv2 MIB; RFC 2096 IP Forwarding Table MIB; RFC 2613 SMON MIB; RFC 2618 RADIUS Client MIB; RFC 2620 RADIUS Accounting MIB; R |
Támogatott hálózati protokollok | RFC 783 TFTP; RFC 951 BootP; RFC 1542 BootP; RFC 854 Telnet; RFC 768 UDP; RFC 792 ICMP; RFC 793 TCP; RFC 826 ARP; RFC 2030 Simple Network Time Protocol; IEEE 802.3x Flow Control; RFC 3376 IGMPv1/v2/v3; IEEE 802.1D Spanning Tree; IEEE 802.1w Rapid Convergence Spanning Tree; IEEE 802.1s Multiple Spanning Trees; IEEE 802.3ad Link Aggregation Control Protocol; IEEE 802.1AB Link Layer Discovery Protocol; RFC 1492 TACACS+; RFC 2138 RADIUS; RFC 2866 RADIUS accounting; SSHv2 Secure Shell; Secure Sockets Layer (SSL); IEEE 802.1X Network Login; IEEE 802.1Q VLANs; IEEE 802.1Q GVRP; IEEE 802.1p Priority; SNMPv1/v2c/v3; HTML and telnet management; RFC 1493 Bridge MIB; RFC 1213 MIB II; RFC 2096 IP Forwarding Table MIB; RFC 2737 Entity MIB; RFC 2863 Evolution of Interface; RFC 2665 Ethernet MIB; RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events); RFC 2021 RMON probe configuration (RMON v2); RFC 2668 802.3 MAU MIB; RFC 2613 SMON; RFC 2674 802.1p and IEEE 802.1Q Bridge MIB; RFC 2618 RADIUS Client MIB; RFC 2620 RADIUS Accounting MIB; RFC 3176 sFlow |
Kialakítás | |
Biztonság | cUL (CSA 22.2 No. 60950); EN 60950/IEC 60950; NOM-019-SCFI-1994; UL 60950 |
Elektromágneses kompatibilitás | FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A; IEC/EN 61000-3-2; IEC/EN 61000-3-3 |
Teljesítmény | |
Processzor frekvencia | 264 MHz |
Memória típusa | SDRAM |
Belső memória | 64 MB |
Flash memória | 16 MB |
Beépített processzor | Igen |
Processzor modell | Broadcom BCM5836 |
Tápellátás | |
Beviteli feszültség | 100-127 / 200-240 VAC |
Áramfogyasztás (tipikus) | 92 W |
Bemeneti áram | 1.5 A |
Tápellátás Etherneten keresztül (PoE) | |
Ethernet-áramellátás (PoE) támogatása | Igen |
További jellemzők | |
Vezérlési plaftorm | HP PCM+; HP PCM; command-line interface; Web browser; configuration menu; out-of-band management |
Várakozási idő | Latency: < 5.4 µs (FIFO 64-byte packets) |
Méret (sz x mé x ma) | 322,6 x 442 x 43,2 mm |
Kapcsolódási technológia | Vezetékes |
Távoli adminisztráció | command-line interface; Web browser; configuration menu; out-of-band management |
Áramkövetelmények | 100-127 VAC/200-240 VAC; 50/60 Hz |
Hálózat jellemzők | Ethernet, Fast Ethernet, Gigabit Ethernet |
Állvány | Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only |
Memória és processzor | Processor: MIPS @ 264 MHz, 16 MB flash, packet buffer size: 1.5 MB, 64 MB SDRAM |
Bemeneti frekvencia | 50 / 60 Hz |
Merevlemez sebessége | 7200 RPM |
Tömeg (imperial) | 8.6 lb. |
UNSPSC-kód | 43222612 |
Üzemi magasság (angolszász mértékegység) | up to 10000 ft. |
Nem üzemi relatív páratartalom (nem kondenzáló) | 15 - 95% |
Igazgatási termék neve | ProCurve Manager Plus; ProCurve Manager |
Be- és kimeneti portok | 44 auto-sensing 10/100/1000 ports(IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T), Media Type: Auto-MDIX, Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only; 4 dual-personality ports, each port can be used as either an RJ-45 10/100/1000 port or an open mini-GBIC slot (for use with mini-GBIC transceivers) |
Elektromágneses immunitás | EN 55024, CISPR 24; IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6; IEC 61000-4-8; IEC 61000-4-11; EN 61000-3-2, IEC 61000-3-2; EN 61000-3-3, IEC 61000-3-3 |
Elektromágneses kibocsátás | FCC Class A; EN55022/CISPR-22 Class A; VCCI Class A; IEC/EN61000-3-2; IEC/EN61000-3-3 |
Beviteli feszültség | 100-127 / 200-240 VAC |
Támogatott protokollok | Network Management Device Management MIBs General Protocols IEEE 802.1X Port Based Network Access Control; RFC 1492 TACACS+; RFC 2138 RADIUS Authentication; RFC 2866 RADIUS Accounting; Secure Sockets Layer (SSL); SSHv2 Secure Shell IEEE 802.1AB Link Layer Discovery Protocol (LLDP); RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events); RFC 3176 sFlow; SNMPv1/v2c/v3 IEEE 802.1D MAC Bridges; IEEE 802.1p Priority; IEEE 802.1Q VLANs; IEEE 802.1s Multiple Spanning Trees; IEEE 802.1w Rapid Reconfiguration of Spanning Tree; IEEE 802.3ad Link Aggregation Control Protocol (LACP); IEEE 802.3x Flow Control; RFC 768 UDP; RFC 783 TFTP Protocol (revision 2); RFC 792 ICMP; RFC 793 TCP; RFC 826 ARP; RFC 854 TELNET; RFC 951 BOOTP; RFC 1542 BOOTP Extensions; RFC 2030 Simple Network Time Protocol (SNTP) v4 RFC 1213 MIB II; RFC 1493 Bridge MIB; RFC 1573 SNMP MIB II; RFC 2021 RMONv2 MIB; RFC 2096 IP Forwarding Table MIB; RFC 2613 SMON MIB; RFC 2618 RADIUS Client MIB; RFC 2620 RADIUS Accounting MIB; R |
Üzemi körülmények | |
Üzemi hőmérséklettartomány (T-T) | 0 - 45 °C |
Tárolási hőmérséklettartomány (T-T) | -40 - 70 °C |
Tömeg és méretek | |
Tömeg | 3,9 kg |